0.5% Accurate Precision CW & Pulse Power Sensors
Superb Accuracy!
Bird's® 7037 Series RF Power Sensor is capable of a stunning 0.5% accuracy for measurements of the CW and pulsed signals. This precision sensor is an invaluable tool for development and production engineers who require the most precise accuracy in lab and semiconductor fab environments. Calibration is NIST traceable.
PRODUCT FEATURES
- Time Domain Display
- Gated power measurements with up to four sets of gates available
- Capable of ±0.5% power measurement accuracy
- NIST traceable calibration
- Measure pulse state widths down to 1us (sensor dependent)
- Measure pulse rep. rates from 10 Hz up to 100 kHz
- Harmonic filtering
- External sync input
- RF Interlock (optional)
- Automate with SCPI command set
BENEFITS
- Enhances the set point accuracy of the RF sources
- Optimizes source-to-source consistency across the fleet
- Delivers power measurements to 0.5% accuracy across its dynamic range
- Simplifies measurements of multilevel pulses
- Streamlines data collection efforts via UI or API
PRODUCT SELECTION GUIDE
Model Number |
Freq. (MHz) |
Power Range |
Pulse Rep Rate |
7037-1-524001-xxyy |
0.4 ± 10% |
25 W to 25 kW |
10 Hz to 11.25 kHz |
7037-1-544301-xxyy |
2.0 ± 10% |
10 W to 10 kW |
10 Hz to 50 kHz |
7037-1-595701-xxyy |
13.56 ± 5% |
100 W to 10 kW |
100 Hz to 100 kHz |
7037-1-605801-xxyy |
27.12 ± 5% |
60 W to 6 kW |
100 Hz to 100 kHz |
7037-1-616101-xxyy |
40.68 ± 5% |
75 W to 7.5 kW |
100 Hz to 100 kHz |
7037-1-625801-xxyy |
60.0 ± 5% |
60 W to 6 kW |
100 Hz to 100 kHz |
Connector Options (xxyy): 7/16 DIN, N, HN, LC, QRM and others that are available on request.
Note:
- The Pulse Power Sensor can measure 4 states within a single pulse.
- Depending on the rep rate, the minimum state width is approximately 1% of the pulse rep rate period.
- Depending on the rep rate, the maximum state width is approximately 99% of the pulse rep rate period.
- For applications with rep rates near the low or high extremes of the spec, consult the user manual for the exact limits.
Item Name
Precision Pulse Sensor
Measurement Type
CW and Multi-State Pulsed RF Power Sensor
Power Range
360 kHz to 63 MHz, Sensor Dependent
Power Measurement Accuracy
0.5% at calibrated frequencies, over entire power range
1.5% at all other frequencies within sensor bandwidth
Insertion Loss
<0.05 dB (max)
Calibration
NIST Traceable
RF Connectors
QC 7/16 DIN, N, HN, LC, QRM and others that are available on request
System
Recommended Calibration Interval: 6 months
Interface: USB 2.0
Power Supply: Via supplied USB Cable
External Sync Input: TTL High, 2-5V; TTL Low, 0-0.85V
Compatible With: Virtual Power Meter (VPM3-MSP) Software
Environmental
Temperature
Operating: 15 to 35 °C (59 to 95 °F)
Storage: -20 to 70 °C (-4 to 158 °F)
Humidity: 95% maximum (non-condensing)
Altitude: 15,000 ft max (4,500 m max)
Physical
Size: 6.0" x 1.9" x 3.7" (155 x 50 x 95 mm)
Not including QC connectors
Weight: Less than 3 lb, 1.4 kg
Certifications
Mechanical Shock and Vibration: Designed to meet MIL-PRF-28800F class 3
EMC
EMC Directive (2004/108/EC)
European Standard: EN 61326—Electrical Equipment for measurement, control and laboratory use; EMC Requirements
Test Spec (for radiated immunity): EN 61000-4-3—Testing and measurement techniques - 10V/meter
CE Mark: Compliant
RoHS: Compliant