7.5 GHz Handheld Spectrum Analyzer
Carry Precision With You
Get clarity and accuracy on your RF frequency circuits with SignalHawk! Our analyzers provide real-time spectrum monitoring and analysis with a wide frequency range from 9 kHz to 7.5 GHz, designed for field engineers, technicians, wireless equipment manufacturers, service providers, contractors, tower erectors and military field personnel. With SignalHawk you can get detailed insight into your radio signals for faster and easier optimization!
Get ready for the next-generation of signal testing and interference mitigation with SignalHawk’s SH-75 analyzer!
With its intuitive touchscreen user interface, best-in-class functionality, expanded Wi-Fi 6E coverage, carrier interference mitigation capabilities and gate scanning for 5G uplink interference, it’s the perfect tool for any industry professional who needs to keep track of signal transmissions up to 7.5GHz.
FEATURES
- Spectrogram/Waterfall display shows intermittent power levels at a glance.
- FM demodulation allows for rapid verification of communications at the specified frequency.
- Predefined measurements scan and discover spectrum events other analyzers miss.
- View the spectrum with trace display, spectrogram display, or both.
- High-resolution, full-color display for indoor or outdoor viewing.
- Rugged and weather resistant.
- Includes the Bird RF Meter App for interoperability with a wide range of Bird Field sensors.
PREDEFINED MEASUREMENTS
- Channel Power
- Adjacent Channel Power Ratio (ACPR)
- Phase Noise
- N dB Down Bandwidth
- Occupied Bandwidth (OBW)
- Field Strength
- FM Demodulation
- CNR Loss (GNSS Signal Quality)
- Spectrum Masking and Limit Lines
- NEW! Gate Scanning
WEBINAR
Item Name
SignalHawk, Handheld Spectrum Analyzer
Frequency
Range: 9 kHz to 7.5 GHz
Span Accuracy: ±1%
Sweep Time
1.2 ms to 1600 s Full Span
3.99 ms to 1600 s Settable Zero Span
Resolution Bandwidth
10 Hz to 5 MHz in 1, 2, 3, 5, 10 Steps
Accuracy: ≥1 MHz, ±10% (<1 MHz, ±2%)
Second Harmonic Distortion
1.6 GHz -70 dBc
Third-Order Intercept --TOI
+15 dBm (–10 dBm tones , 1 MHz apart, Preamp Off, Reference Level –10 dBm)
Phase Noise
-88 dBc/Hz,@10 kHz (typical -90 dBc/Hz)
-115 dBc/Hz,@1 MHz (typical -116 dBc/Hz)
Measurement Range
DANL to +20 dBm
Input Attenuator
Range: 0 to 30 dB, 1 dB step
Uncertainty: ±0.6 dB
Max Safe Input Level
Preamp Off: +30 dBm
Preamp -20 dB: 0 dBm
Preamp +40 dB: -20 dBm
Reference Level Range
-140 dBm to +20 dBm
-190 dBm to +70 dBm
(Ref Level Offset: ON)
RBW Switching Uncertainty
±0.3 dB
Display Average Noise Level -- DANL
Preamp Off: 1 GHz, -129 dBm/Hz (typical -132 dBm/Hz)
Preamp +20 dB: 1 GHz, -149 dBm/Hz (typical -152 dBm/Hz)
Preamp +40 dB: 1 GHz, -168 dBm/Hz (typical -169 dBm/Hz)
(Input terminated, Detector set to Positive, Trace Average set to 1000, Span set to 50 kHz, Reference level of -100 dBm, all other settings auto-coupled, 23±5 °C normalized to 1 Hz RBW)
Residual Responses
-60 dBm
Amplitude Accuracy
±1.5 dB (ATT set to 0 dB , input signal -5 to -30 dBm, Detector set to Positive, Sensitivity set to Low, RBW auto-coupled, all other settings auto-coupled, 23±5 °C. Half hour warm-up required.)
Reference Level Accuracy
≥ -60 dBm, ±0.8 dB
Connectors
RF In: N (Female)
USB: USB type C
Power Interface: Slim Tip, DC 20V
Display
5.5 in, 1280 x 720 pixel
Languages
English, Chinese
Battery
Type: Li-ion
Operating Time: 5 hours (typ)
Charge Time: 6 hours (typ)
Temperature Range
Operating: 0 to 50 °C
Storage: -20 to 70 °C
Dimensions
7.8 in x 3.7 in x 2.4 in (197 mm x 93 mm x 61 mm)
Standard Accessories
Hard Carrying Case, Soft Carrying Case, AC Adapter (12 Vdc Ouput), Stylus, USB Drive, USB Adapter, Manual and Battery