SCC8 Series

Lab Grade Calibration Cart, High Power


SCC8 Series, Calibration Carts are designed for immediate, effortless use. It has three primary components. The 4421 Multifunction Power Meter displays RF power. 4028 Series Power Sensors are highly accurate sensors that measure RF power without requiring calibration or external couplers or attenuators. Bird Moduloads are low reflection 50 Ohm terminations that can dissipate up to 10 or 25kW. These components are installed into a cart for easy transportation. The cart is suitable for use in a clean room environment and is equipped with four swivel casters for maximum maneuverability.

Features
  • The mobile cart is stainless steel and has locking wheels
  • High return loss ensures minimal power measurement error contribution
  • Available in international and domestic versions
  • Service plans available with Bird Service Center

Note: See datasheet for build options

SCC8 Series, Calibration Cart
SCC8 Series
Downloads:
product specifications:
Item No
SCC8 Series
Item Name
High Power Calibration Cart
Frequency Range
250 kHz - 30 MHz, depending on sensor
Power Levels
10 kW or 25 kW
Accuracy
±2% (2s) of reading at calibration frequency and power levels
±4% (2s) of reading at other power levels and frequencies within sensor range (add 2% to uncertainty outside 25 ± 10 °C)
RF Sensors Options
4028 Series (see datasheet)
VSWR
Sensor: 1.05 max (32.2 dB return loss)
Load: 1.1 max (26.4 dB return loss)
Particle Generation
156 per cfm (0.5 µm)
29 per cfm (1 µm)
0 per cfm (3 µm)
Connectors
Customer specified, appropriate for power level
For connector options, please refer to our catalog or contact sales at 866.695.4569 or sales@birdrf.com
Impedance Ω
50 Ohms
Construction
Stainless steel cart with (4) locking swivel casters
Power Requirements
115 VAC ± 10%, 60 Hz, 11 A (nom)
230 VAC ± 10%, 50 Hz, 5.5 A (nom)
Temperature
Operating:
+5 to + 30 °C, £ 25 kW, 100% water, derate sensor accuracy outside 25 ± 10 °C
+5 to + 45 °C, < 20 kW, 100% water, derate sensor accuracy outside 25 ± 10 °C
0 to + 25 °C, £ 25 kW, 35% ethylene glycol / 65% water
0 to + 25 °C, < 20 kW, 35% ethylene glycol / 65% water

Storage:
+5 °C to + 50 °C, 100% water
-20 °C to + 50 °C, 35% ethylene glycol / 65% water
Coolant
100% water or 35% industrial ethylene glycol / 65% water, 9 quarts (8.5 liters), forced air cooling
Humidity
5% (max), non-condensing
Altitude
Load derated above 5,000 feet (1,524 m)
Dimensions
(L x W x H)
39.5” x 21.5” x 39.5” (100.3 cm x 54.6 cm x 100.3 cm)
Weight
240 lbs (109 kg)
compatible devices:
4028 Series
2% Accurate, Precision Power Sensors