Bird - The RF Experts
61-88-50 Series
61-88-50 Series, 900 MHz Band, Signal Booster II
61-88-50 Series
Mission Critical Reliability for In-Building Coverage
61-88-50 Series, 900 MHz Band, Signal Booster II provides Public Safety grade communications and reliability in disadvantaged RF locations for First Responders, Public Safety/Governmental agencies and Private system Users. Mission-critical communications are ensured in challenging environments such as basements, parking garages, correctional facilities, courthouses, hospitals, high-rise buildings, schools and universities, airports, subways and rapid transit systems, and stadiums.

Frequencies MUST be provided with order

Models
61-88-X-Y05-Z
61-88-X-Y06-Z


X = Type 50: Standard, 60: RescueLine
Y = Gain A=80 dB, B=60 dB, C=45 dB
Z = Housing Options G1: Painted Steel NEMA 4, G2: Stainless Steel NEMA 4X, RM: 19" Rack Mount, N: NFPA 

Model Number Example 61-88-50-A06-G1

Please Contact Factory 716.549.4700 for non-standard configurations with custom frequency, windows and bandwidths.

Class B Type Booster. Type Acceptance under FCC Rules Part 90 and Industry Canada Certification part RSS-131

Warning: This is NOT a CONSUMER device. It is designed for installation by FCC Licensees and Qualified Installers. You must have an FCC license or express consent of an FCC Licensee to operate this device. Unauthorized use may result in significant forfeiture penalties, including penalties in excess of $100,000 for each violation.

Request Info
61-88-50 Series, 900 MHz Band, Signal Booster II
61-88-50 Series
Downloads:
product specifications:
Item No
61-88-50 Series
Item Name
900 MHz Band, Signal Booster II
Frequency Range
61-88-50-#05-XX:
LF: 896-901 MHz;
HF: 935-940 MHz

61-88-50-#06-XX:
LF: 896-902 MHz;
HF: 935-941 MHz
Passband Frequencies
61-88-50-#05-XX:
5 MHz

61-88-50-#06-XX:
6 MHz
Gain
45
60
80
(depending on model)
Gain Adjustment
Programmable 0-30 dB, 0.5 dB increments
3rd Order Output Intercept Point
+55 dBm min., with no attenuation
Maximum Input Level
0 dBm
Maximum Output Power
+35 dBm (single carrier)
RF Sampler
PA Output sampler ports
Noise Figure - without attenuation
6.5 dB max.
3.5 dB (for High Gain unit)
Propagation Delay
<1 µs
Operating Temperature Range
-30 to +50 °C
Impedance Ω
50
VSWR
<1.5:1
Input-Output Connectors
N
RF Sampler Connectors
BNC
AC Power Input
100-240 VAC; 50-60 Hz
DC Input Voltage
+24 to +27 VDC [-48 VDC Optional]
Unit Power Consumption AC-DC
<150 VA
Housing
Options:
G1 - (Painted Steel - NEMA 4)
G2 - (Stainless Steel - NEMA 4X)
RM - (19" Rack Mount)
Dimensions
24" x 24" x 8" (609.59 x 609.59 x 203.2 mm)
Net Weight
<85 lbs. (< 38.5 kg.)
FCC Certification
EZZ5PI618850
(Class B Type Booster Equipment Authorization under FCC Rules Part 90)
Industry Canada Certification
1940A-PI618850
(Canada Certification Part RSS-131)